Skip to main content
Connect Icinga 2 so CloudThinker can check hosts, services, problems, and downtimes, and, if you allow it, acknowledge a problem, run a check now, or set downtime. The connection signs in to the Icinga 2 REST API as an ApiUser with a password, and can do only what that user’s permissions allow.

Prerequisites

  • An Icinga 2 API that CloudThinker can reach over HTTPS, by default on port 5665. For a private address, follow Reaching private services.
  • Access to the Icinga 2 configuration on the master, to add an ApiUser and copy its CA certificate.
  • The Admin role in your CloudThinker workspace. See Roles.

Setup

1

Create an ApiUser

On the Icinga master, add an ApiUser object, for example in /etc/icinga2/conf.d/api-users.conf. Give it a strong password and only the permissions in Required permissions:
Restart Icinga 2 to load it. See Icinga’s API user instructions.
2

Copy the CA certificate

Icinga signs its API certificate with its own certificate authority by default. Copy the CA certificate from the master, usually /var/lib/icinga2/certs/ca.crt.
3

Connect in CloudThinker

Open Settings → Workspace → Connections, open the Discover tab, and select Icinga. Click Connect, fill in the fields below, then click Connect in the dialog.Success state: the connection shows a Connected status with your Icinga version. CloudThinker then opens a chat that takes a read-only deep look at the connection (“Often takes about 15 min. You can leave the chat.”). To run it again later, open the card’s More menu and choose Try in chat.

Connection details

CloudThinker checks that the API certificate matches the host name in API URL, so use the name the certificate was issued for. It also refuses redirects.

Required permissions

Start with the four query permissions only. Agents can still investigate every host, and no approval, mistaken or automatic, can change anything in Icinga.

Agent capabilities

Reads run without asking. Each change targets one host or service, and the agent reads it again afterwards to confirm the change. A downtime starts at once and lasts from 1 minute to 7 days. A downtime on a host covers every service on that host, and the agent says so before it asks. Agents cannot change configuration, add hosts, or send custom notifications. Make those changes in Icinga. Writes also need Allow writes on, which starts on. To lock writes in CloudThinker, open Icinga in Settings → Workspace → Connections and turn off the Allow writes switch on its detail panel. Every change an agent makes goes through your workspace’s Approvals first. On the default Auto · Rules + AI · Ask me mode, AI judgment can let a safe change run without asking — and an Allow Rule can too. Choose Manual to approve every change yourself.

Verify the connection

Expect your Icinga version with real host and service names. A failed section is unavailable data, not zero problems.

Example prompts

Troubleshooting

Check the ApiUser name and password in the Icinga configuration, then edit the connection and paste them again.
Add status/query and the objects/query permissions to the ApiUser, restart Icinga 2, and connect again. If a change fails later with a permission error, add the matching actions/ permission.
The address points at Icinga Web or another service. Enter the Icinga 2 API address with its port, such as https://icinga.example.com:5665, and no path.
Enter the API address Icinga 2 serves directly, not an address that forwards to it.
Paste that file into CA certificate (optional). If CloudThinker says the CA certificate is not valid PEM, paste the full certificate, including its BEGIN and END lines. If the error stays, the host name in API URL does not match the API certificate.
CloudThinker could not open a connection to that address. Confirm the URL starts with https://, includes the API port, and that your firewall lets CloudThinker reach it. Browser access from your laptop alone is not enough.
Allow writes is off on this connection, so the change was refused and nothing changed. Turn it on in the connection’s detail panel, or make the change in Icinga.

Security

  • Least privilege — grant only the permissions the agents need for your use case; start read-only and widen later.
  • Read-only by default — use read-only credentials unless you want agents to make changes through this connection.
  • Rotate credentials — rotate keys and tokens on your normal schedule; CloudThinker picks up the new value when you update the connection.
  • Revoke on offboarding — remove the credential at the provider when you delete a connection or a teammate leaves.
  • Use a dedicated ApiUser for CloudThinker with an explicit permission list. Never use *.
  • Port 5665 also carries cluster traffic between Icinga nodes. Limit who can reach it with your firewall.

Approval rules

Decide which Icinga changes run, wait for a person, or are refused.

Checkmk